Allows you to specify a project-wide or individual timing assignment name. You can make individual timing assignments to pins and/or registers when you select Edit specific entity & node settings for in the By Node tab of the Assignment Organizer dialog box (Assignment menu). You can specify project-wide timing assignments when you select Edit project defaults & Compiler settings in the By Node tab of the Assignment Organizer dialog box. You can also specify project-wide timing assignments using the Timing Wizard (Assignments menu) or the Settings command (Assignments menu). You can view and edit the following types of project-wide and individual timing assignments with the Assignment Organizer dialog box:
Assignment Name | Setting | Assignment Type |
---|---|---|
Clock Settings | <clock settings name> | Individual |
Cut Off Clear and Preset Signal Paths | On | Off | Project-wide |
Cut Off Feedback from I/O Pins | On | Off | Project-wide |
Cut Off Read During Write Signal Paths | On | Off | Project-wide |
Cut Paths between Unrelated Clock Domains | On | Off | Project-wide |
Cut Timing Path | On | Off | Individual |
Default Multicycle Hold | One | Same As Multicycle | Project-wide |
Enable Multicycle | <number of clock cycles> | Individual |
Enable Multicycle Hold | <number of clock cycles> | Individual |
Enable Source Multicycle | <number of clock cycles> | Individual |
Enable Source Multicycle Hold | <number of clock cycles> | Individual |
External Input Delay | <delay value> | Project-wide and individual |
External Output Delay | <delay value> | Project-wide and individual |
fmax Requirement | <requirement value> | Project-wide |
Ignore Clock Settings | On | Off | Project-wide |
Include External Pin Delays in fmax Calculations | On | Off | Project-wide |
Inverted Clock | On | Off | Individual |
Minimum Delay Requirement | <delay value> | Individual |
Multicycle | <number of clock cycles> | Individual |
Multicycle Hold | <number of clock cycles> | Individual |
Not a Clock | On | Off | Individual |
Number of Source Nodes to Report | <value> | Project-wide |
Run All Timing Analyses | On | Off | Project-wide |
Source Multicycle | <delay value> | Individual |
Source Multicycle Hold | <delay value> | Individual |
tco Requirement | <requirement value> | Project-wide and individual |
th Requirement | <requirement value> | Project-wide and individual |
tpd Requirement | <requirement value> | Project-wide and individual |
tsu Requirement | <requirement value> | Project-wide and individual |
- PLDWorld - |
|
Created by chm2web html help conversion utility. |