STP

Running the SignalTap II Logic Analyzer



To run the SignalTap® II Logic Analyzer:

  1. If you have not already done so, perform an analysis and synthesis, an analysis and elaboration, or a compilation on the design.

  2. If necessary, open a SignalTap II File (.stp), or create a new STP File.

  3. Set up the STP File.

  4. Save the STP File.

  5. If you have not compiled the SignalTap II Logic Analyzer into the project, or if you have made changes that require recompilation, compile the STP File with the selected project.

  6. Program a device in the SignalTap II Logic Analyzer.

  7. Select the instance(s) that you want to run in the Instance Manager.

  8. Choose Run Analysis (Processing menu). Shortcut More Details

  9. Analyze the SignalTap II data.

 


Back to Top

- PLDWorld -

 

Created by chm2web html help conversion utility.