mti_AddQuitCB()
Adds a simulator exit callback.
Syntax
mti_AddQuitCB( func, param )Returns
Arguments
Name Type Description func mtiVoidFuncPtrT A pointer to a function to be called when the simulator exits param void * A parameter to be passed to the function; OPTIONAL - can be NULLDescription
mti_AddQuitCB() adds the specified function to the simulator exit callback list. The same function can be added multiple times, with possibly a different parameter each time. When the simulator exits, all callbacks in the list are called with their respective parameters.
When the "quit -sim" command is given to vsim, quit callbacks are not called because the simulator is not quitting completely. Instead, restart callbacks are called.
Related functions
Example
FLI code
#include <stdlib.h> #include <mti.h> void quitCallback( void * param ) { mti_PrintFormatted( "Cleaning up %s for simulator exit ...\n", (char *)param ); free( param ); } void initForeign( mtiRegionIdT region, /* The ID of the region in which this */ /* foreign architecture is instantiated. */ char *param, /* The last part of the string in the */ /* foreign attribute. */ mtiInterfaceListT *generics, /* A list of generics for the foreign model.*/ mtiInterfaceListT *ports /* A list of ports for the foreign model. */ ) { char * instance_info; instance_info = malloc( strlen(param) + 1 ); strcpy( instance_info, param ); mti_AddQuitCB( quitCallback, instance_info ); }HDL code
entity for_model is end for_model; architecture a of for_model is attribute foreign of a : architecture is "initForeign for_model.sl; for_model"; begin end a; entity top is end top; architecture a of top is signal s1 : bit := '0'; component for_model is end component; for all : for_model use entity work.for_model(a); begin i1 : for_model; s1 <= not s1 after 5 ns; end a;Simulation output
% vsim -c top Reading .../modeltech/sunos5/../tcl/vsim/pref.tcl # 5.4b # vsim -c top # Loading .../modeltech/sunos5/../std.standard # Loading work.top(a) # Loading work.for_model(a) # Loading ./for_model.sl VSIM 1> quit # Cleaning up for_model for simulator exit ...
![]() Model Technology Inc. Voice: (503) 641-1340 Fax: (503)526-5410 http://www.model.com sales@model.com |
![]() |
![]() |
![]() |
![]() |