Table of Contents Previous page Next page Index

ModelSim Documentation Bookcase

Model Technology Inc.


Rounded timing values

The SDF TIMESCALE construct specifies time units of values in the SDF file. The annotator rounds timing values from the SDF file to the time precision of the module that is annotated. For example, if the SDF TIMESCALE is 1ns and a value of .016 is annotated to a path delay in a module having a time precision of 10ps (from the timescale directive), then the path delay receives a value of 20ps. The SDF value of 16ps is rounded to 20ps. Interconnect delays are rounded to the time precision of the module that contains the annotated MIPD.


Model Technology Inc.
Model Technology Incorporated
Voice: (503) 641-1340
Fax: (503)526-5410
www.model.com
sales@model.com
Table of Contents Previous page Next page Index

ModelSim Documentation Bookcase